Technical Specification
|
|
Max Power | : |
400W. | |
Interface | : |
Touch Screen. | |
Programs | : |
100. | |
Monopolar Cut Modes | : |
Pure Cut, Precise Cut, Blend 1, Blend 2, | |
Blend 3, Blend 4, Blend 5, Endocut 1, | |||
Endocut 2, Endocut 3. | |||
Monopolar Coagulation Modes | : |
Coarse Spray, Fine Spray, Dessicate, | |
Coarse Fulgurate, Fine Fulgurate. | |||
Bipolar Modes | : |
1 Bi-cut, Macro, Micro. | |
Tissue Response Circuit | : |
Present. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
400W. | |
Display | : |
Graphical LCD Display. | |
Programs | : |
99. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2, Endo Cut. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulgurate. | |
Bipolar Modes | : |
Micro, Macro, Cut. | |
Tissue Response Circuit | : |
Present. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
400W. | |
Display | : |
Graphical LCD Display. | |
Programs | : |
20. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2, Endo Cut. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulgurate. | |
Bipolar Modes | : |
Micro, Macro, Cut. | |
Tissue Response Circuit | : |
Present. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
400W. | |
Display | : |
7 Segment LED Digital. | |
Programs | : |
20. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2, Endo Cut. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulgurate. | |
Bipolar Modes | : |
Micro, Macro, Cut. | |
Tissue Response Circuit | : |
Present. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
400W. | |
Display | : |
7 Segment LED Digital. | |
Programs | : |
NA. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2, Endo Cut. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulgurate. | |
Bipolar Modes | : |
Micro, Macro, Cut. | |
Tissue Response Circuit | : |
Present. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
400W. | |
Programs | : |
NA. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulguration. | |
Bipolar Modes | : |
Coag. | |
Tissue Response Circuit | : |
NA. | |
Patient Plate Monitoring System | : |
Present. | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
300W. | |
Display | : |
7 Segment LED Digital. | |
Programs | : |
6. | |
Monopolar Cut Modes | : |
Pure Cut, Blend1, Blend2, Endo Cut. | |
Monopolar Coagulation Modes | : |
Spray, Dessicate, Fulgurate. | |
Bipolar Modes | : |
Micro, Macro. | |
Tissue Response Circuit | : |
Present | |
Patient Plate Monitoring System | : |
Present | |
Dimension (WxHxD) & Weight | : |
300 mm x 150 mm x 340 mm & 5.5 kg. |
|
|
Technical Specification
|
|
Max Power | : |
300W | |
Programs | : |
NA | |
Monopolar Modes | : |
Cut, Coagulation. | |
Bipolar Modes | : |
Cut, Coag. | |
Tissue Response Circuit | : |
NA. | |
Patient Plate Monitoring System | : |
NA. | |
Dimension (WxHxD) & Weight | : |
3.5" x 13"x 12" & 3 kg. |